CRESTRON AMP-4600
4-Channel Power Amplifier, 600W/Ch.
Robust and efficient amplification, designed to complement Crestron Avia™ Digital Signal Processors.
Communications | |
Ethernet | 10/100 Mbps, auto-switching, auto-negotiating, auto-discovery, full/half duplex, TCP/IP, UDP/IP, CIP, DHCP, SSL, SSH, SFTP (SSH File Transfer Protocol) |
USB Device | USB device port for computer console (setup) |
Audio | |
Input Signal Types | Balanced or unbalanced analog line-level |
Output Signal Types | 4/8 Ohm, 70 or 100 Volt direct-coupled |
Operating Modes (Configurable via Avia Audio Tool software) |
Mono: Each channel is configurable to operate independently from all other channels; |
Output Power |
600 Watts per channel @ 4-8 Ohms or 70/100 Volts nominal |
Power Throttle | 600, 500, 400, 300, 250, 200, 150, 125, 100, 75, 50 Watts per channel |
Frequency Response | 20 Hz to 20 kHz ±0.5 dB at 1 Watt, 4-8 Ohms; 200 Hz to 20 kHz ±0.5 dB at 1 Watt, 70/100 Volts |
High Pass Filter | -3 dB @ 80 Hz, 12 dB per octave in 70V or 100V mode |
THD+N | <0.05% @ 1 kHz at 3 dB below clipping |
S/N Ratio | >103 dBA, 20 Hz to 20 kHz |
Channel Separation | >70 dB |
Input Sensitivity | 1.29 Vrms, +4 dBu (balanced) for full rated output power |
Fault Protection | Over Current: Protects each channel individually against an excessive speaker load or shorted speaker line; DC Offset: Protects each channel and speaker line against DC voltages sensed at each output; Over Temperature: Protects the amplifier power supply and each channel against overheating due to poor ventilation or excessive temperature; Under Voltage: Protects the amplifier if the internal power supply voltage is below tolerance due to excessive output levels or insufficient line voltage; Note: All faults report to the control system, and indicate on the front panel and in the software tool. |
Output Relays | Disconnects the speaker line at each output under fault conditions, and during startup and shutdown |
Audio Ramp | Ramps each channel’s audio level up to its last used setting after the corresponding output relay has closed following startup or fault recovery; ramp time 130 milliseconds |
Connectors | |
LINE INPUTS 1 – 4 | (4) 3-pin 3.5 mm detachable terminal blocks; Balanced line-level audio inputs; Maximum Input Level: 12.3 Vrms, +24 dBu; Input Impedance: 20k Ohms balanced |
SPEAKER OUTPUTS 1 – 4 | (4) 2-pin 7.62 mm reversed gender 20A detachable terminal blocks; Power amplifier outputs; Wire Size: Terminals accept up to 12 AWG (3.31 mm²); Note: Output is direct-coupled in all modes for all load types, not transformer isolated |
LAN | (1) 8-pin RJ45 female; 10Base-T/100Base-TX Ethernet LAN port |
100-240V~ 50/60Hz 4A-2A | (1) IEC 60320 C14 main power inlet; Mates with removable power cord (included) |
G | (1) 6-32 screw; Chassis ground lug |
COMPUTER (front) | (1) USB Type B female; USB computer console port (for setup only) |
Controls & Indicators | |
PWR | (1) Bi-color green/amber LED, indicates operating power supplied from AC line power, amber indicates startup in progress, green indicates normal operation, alternating green/amber indicates absence of a network connection |
RESET | (1) Recessed pushbutton, restores last saved settings |
STATUS, FAULT 1 – 4 | (4) Red LEDs, each indicates an under-voltage fault condition on the corresponding channel |
STATUS, CURRENT 1 –4 | (4) Blue LEDs, each indicates an over-current fault condition on the corresponding output |
STATUS, DC 1 – 4 | (4) Blue LEDs, each indicates a DC offset fault condition on the corresponding channel |
STATUS, THERM 1 – 4 | (4) Blue LEDs, each indicates an over-temperature fault condition on the corresponding channel |
STATUS, 70V-100V 1 – 4 | (8) Blue LEDs, each indicates the corresponding channel is configured for 70 Volt / 100 Volt operation |
VU 1 – 4 | (4) 5-segment LED bar graph audio level meters for each corresponding output; each contains (4) blue LEDs for -40dB, -30dB, -20dB, and -10dB, and (1) red LED for CLIP |
LINE INPUTS 1 – 4 (rear) | (4) Screwdriver-adjustable rotary controls, each adjusts the input attenuation level for the corresponding channel |
LAN (rear) | (2) LEDs, green LED indicates Ethernet link status, amber LED indicates Ethernet activity |
SETUP (rear) | (1) Red LED and (1) pushbutton for Ethernet setup, flashes while updating firmware |
Power Switch (rear) | (1) Rocker switch, turns main power on or off |
Circuit Breaker Reset (rear) | (1) Push button switch, resets 10A circuit breaker |
Power | |
Main Power | 4-2 Amps @ 100-240 Volts AC, 50/60 Hz, 10 Amps max. |
Input Power | 300 Watts |
Power Consumption | 300 Watts, all channels driven at 1/8th output power; 70 Watts, all channels idle |
Environmental | |
Temperature | 41° to 104°F (5° to 40°C) |
Humidity | 10% to 90% RH (non-condensing) |
Heat Dissipation | 1025 BTU/hr, all channels driven at 1/8th output power; 240 BTU/hr, all channels idle |
Construction | |
Chassis | Metal, variable-speed fan-cooled, vented sides |
Front Panel | Metal, black finish with polycarbonate label overlay |
Mounting | Freestanding or 1 RU 19-inch rack-mountable (front rack ears and rear support brackets included) |
Dimensions | |
Height | 1.72 in (44 cm) |
Width | 17.26 in (436 mm); 19.00 in (483 mm) with rack ears |
Depth | 14.59 in (371 mm) |
Weight | |
14.1 lb (6.4 kg) | |
Compliance | |
UL 60065, FCC Class A commercial use |
Click here to search product certificates.
- Crestron XiO Cloud connectivity requires a subscription. For more information about XiO Cloud, please visit https://www.crestron.com/xiocloud.
- Integration with Crestron Fusion requires a control system and custom programming.
This product may be purchased from an authorized Crestron dealer. To find a dealer, please contact the Crestron sales representative for your area. A list of sales representatives is available online at www.crestron.com/salesreps or by calling 800-237-2041.
The specific patents that cover Crestron products are listed online at: patents.crestron.com.
Certain Crestron products contain open source software. For specific information, please visit www.crestron.com/opensource.
Crestron, the Crestron logo, Avia, Crestron Fusion, Crestron XiO Cloud, Saros, and Vector are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography. Specifications are subject to change without notice. ©2019 Crestron Electronics, Inc.